      Current: Products> Medical Equipments > >Portable Patient Monitor

      Product customization service

      Most of the company's products can provide a full range of customized services including product materials, models, functions, packaging. Please contact customer service staff for details.

      Through more than ten years of medical and health product export services, we have accumulated a wealth of industry experience, and can provide professional and personalized services to meet the needs of different customers around the world for personalized and branded customized medical products.

      Portable Patient Monitor
      Quick Details
      • Type:
      • First-Aid Devices
      • Brand Name:
      • Hiprove
      • Model Number:
      • HPL-9000
      • Place of Origin:
      • Shandong, China (Mainland)
      • Product name:
      • Medical Portable ICU Patient Monitor with good price ISO CE approved
      • Certificate:
      • CE ISO
      • Warranty:
      • 1 year
      • Size:
      • 12.1"
      • Display:
      • Multi channel display
      •  
      Packaging & Delivery
      • Packaging Details:
      • 422637cm, 1 set/carton
      • Delivery Time:
      • Shipped in 30 days after payment
      Product Description

       

      Medical Portable ICU Patient Monitor with good price

       

      Features:

      12.1" color TFT LCD screen, resolution: 800*600
      5 kinds of interfaces: Standard/Big font/6-lead ECG/Trend gragh/OxyCRG
      Maximum 8-channel waveforms display, the waveform color can be defined by user (7 colors)
      96-hour storage and review of trend graphic gram and table, 400 groups NIBP data, 1800 alarm events
      ST and arrhythmia analysis, pacemaker analysis, drug dose calculation
      Anti-defibrillation design
      NIBP over pressure protection
      Plug-in rechargeable battery, AC/DC available
      Support wire or wireless network

      Standard: 3/5-Lead ECG, RESP, SpO2, NIBP, PR, TEMP

      Options: Nellcor SpO2, Mainstream/Sidestream EtCO2, 1/2 channel IBP, Touch screen,

      Thermal Recorder, Wall mount, Trolley

       

      Technical Specifications:

      ECG
      Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
      Lead selection: I, II, III, avR, avL, avF, V
      Wavef orm: 2 ch
      Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
      Lead selection: I, II, III,
      Wave form: 1 ch
      Gain: 2.5mm/mV, 5.0mm/mV,
      10mm/mV,20mm/mV, auto
      HR and Alarm Range: Adult 15 ~ 300 bpm
      Neo/Ped 15 ~ 350 bpm

      Accuracy: ±1% or±1bpm, which is greater
      Resolution: 1 bpm
      Sensitivity: > 200 (uVp-p)
      Differential Input Impedance: > 5 MΩ

      CMRR : Monitor > 105 dB
      Operation > 105 dB
      Diagnosis > 85 dB
      Electrode offset potential: ±300mV
      Leakage Current: < 10 uA
      ECG Signal Range: ±8 m V ( Vp-p )
      Bandwidth:
      Surgery: 1 ~ 20 Hz
      Monitor: 0.5 ~ 40 Hz
      Diagnostic: 0.05 ~ 130 Hz
      Calibration Signal: 1 (mVp-p), Accuracy:5%
      ST Segment Monitoring Range
      Measure and Alarm -2.0 ~ +2.0 mV
      ARR Detecting:
      Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY,
      TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP,
      PNC,Alarm Available,Review Available


      RESP

      Method : Impedance between R-F(RA-LL)
      Differential Input Impedance: > 2.5 MΩ
      Measuring Impedance Range: 0.3~3 Ω
      Base line Impedance Range: 200~4 KΩ
      Bandwidth: 0.1~2.5Hz
      Resp. Rate:
      Measuring and Alarm Range
      Adult 0 ~ 120 Brpm
      Neo/Ped 0 ~ 150 Brpm
      Resolution 1 Brpm
      Accuracy ±2 Brpm
      Apnea Alarm: 10 ~ 40 S

       

      NIBP

      Method: Oscillometric
      Mode: Manual, Auto, STAT
      Measuring Interval in AUTO Mode :
      1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
      Measuring Period in STAT Mode: 5 Min
      Pulse Rate Range : 40 ~ 240 bpm
      Alarm Type : SYS, DIA, MEAN
      Measuring and alarm range:
      Adult Mode
      SYS: 40 ~ 270 mmHg
      DIA: 10 ~ 215 mmHg
      MEAN: 20 ~ 235 mmHg
      Pediatric Mode
      SYS: 40 ~ 200 mmHg
      DIA: 10 ~ 150 mmHg
      MEAN: 20 ~ 165 mmHg
      Neonatal Mode
      SYS: 40 ~ 135 mmHg
      DIA: 10 ~ 100 mmHg
      MEAN: 20 ~ 110 mmHg
      Resolution: 1mmHg
      Accuracy: Maximum Mean error ±5mmHg
      Maximum Standard deviation ±8mmHg
      Overpressure Protection
      Adult Mode: 297±3 mmHg
      Pediatric Mode: 240±3 mmHg
      Neonatal Mode: 147±3 mmHg
       

      SpO2
      Measuring Range: 0 ~ 100 %
      Alarm Range: 0 ~ 100 %
      Resolution: 1 %
      Accuracy: 70% ~ 100% 2 %
      0% ~ 69%
      Actualization intervalabout: 1 Sec.
      Alarm Delay: 10 Sec.
      Pulse Rate:
      Measuring and Alarm Range 20~300 bpm
      Resolution: 1bpm
      Accuracy: ±3bpm
       

      TEMP
      Channel: 2
      Measuring and Alarm Range : 0 ~ 50 ℃
      Resolution: 0.1 ℃
      Accuracy : ±0.2 ℃
      Actualization intervalabout: 1 Sec.
      Average Time Constant: < 10 Sec.


      IBP

      Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
      Measuring and alarm range:
      ART 0 ~ 300 mmHg
      PA -6 ~ 120 mmHg
      CVP/RAP/LAP/ICP-10 ~ 40 mmHg
      P1 / P2-10 ~ 300 mmHg
      Press Sensor:
      Sensitivity: 5 uV/V/mmHg
      Impedance: 300-3000Ω
      Resolution: 1 mmHg
      Accuracy: ±2% or 1mmHg which is greater
      Actualization interval : about 1 secretar
       

      Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
      Optional: Nellcor SpO2, EtCO2, IBP,TEMP-2, Thermal Recorder,Wall Mount,Trolly,Central station

       

       